CCO Design FP-100Home FP-200Services FP-300Contact
Project CCO DesignLocation Nashville, TN  ·  Scale NTS
Call615.637.6222
CCO Design
PLAN NORTH
FP-101Overview

Drawings that make sense in the field.

Fire sprinkler layouts, coordination and hydraulic calculations delivered accurately, on time and code-compliant when your team needs additional capacity.

PROJECT CCO DESIGN
LOCATION NASHVILLE, TN
SCALE NTS
FP-102Why it works

Drawn for the people who install it.

General contractors and sprinkler contractors use our drawings in three places: the model, the field and the review desk.

01

Coordinated before it’s hung.

We work your sprinkler layout against structure, duct and other trades in the model, so clashes get settled on screen instead of overhead.

02

Your crew reads it once.

Clear dimensions, hanger points and elevations mean fitters install from the sheet, not from phone calls to the office.

03

Drawn for the plan reviewer, too.

Drawings and hydraulic calcs are laid out the way reviewers expect, giving your submittal a better shot at approval on the first round.

FP-104Scope & standards

What we design to.

Layouts, details and calculations are prepared to the NFPA standard that governs the system and the edition your AHJ has adopted.

STANDARDS SCHEDULE
StandardCoversTypical project types
NFPA 13Installation of sprinkler systemsCommercial, industrial, warehouse, high-rise
NFPA 13DSprinkler systems in one- and two-family dwellings and manufactured homesSingle-family homes and duplexes
NFPA 13RSprinkler systems in low-rise residential occupanciesMultifamily, wood-frame and podium
NFPA 14Standpipe and hose systemsHigh-rise and complex structures
NFPA 20Installation of stationary fire pumpsFire pump rooms for high-rise, warehouse and industrial buildings
NFPA 24Private fire service mainsSite underground and fire service entries
FP-104.1Start here

What’s on your table?

Pick the one that sounds like this week.

Response AShop drawings

A set your fitters can build from.

Layouts and details drawn to the NFPA standard and the edition your AHJ has adopted, laid out the way plan reviewers expect to read them.

  • Fewer comments back from plan review
  • Details your fitters don’t have to guess at
  • Ready for submittal and install
Let’s talk about your project→
FP-105A note from John
John Cloninger, CCO Design
John CloningerCCO
A drawing is not just a document. It’s how the whole project team talks.

Fire sprinkler design should serve the people who rely on it: contractors, project managers, fitters, engineers, AHJs and owners. A drawing is a communication tool, a coordination tool, and often the difference between a project that moves smoothly and one that creates unnecessary friction.

Our role is to provide dependable design capacity when your team needs support, while keeping the focus on clean documentation, code-compliant design, practical coordination and work that holds up in the field.

That is the standard we are building around.

— John Cloninger, CCO Design
FP-106Next sheet

Let’s draw your next one.

Start a project→